DALI (GII) Dimmable ECG for Current Sourced LED Modules
Misprints and technical changes excepted
Edition October 2013
OPTOTRONIC
LINEAR (non-isolated)
OTi DALI 90/220-240V/1A0 LT2 L (SMART Interface)
Fit for SMART Grid
Diversity. Quality. Efficiency.
Easy. Flexible. FIT.
Driver product features
Supply voltage: 198-264 V (AC) / 176-276 V (DC)
Output Data: 54-240 V / 250-1000 mA / 1.5-90 W
Line frequency: 0 Hz, Pulsating DC, 50 - 60 Hz
Suitable for use in emergency lighting systems as per EN
50172/DIN VDE 0108-100
Dimming range: 1 to 100 % luminous flux (Combi PWM /
Linear Dimming)
Energy efficiency > 92 % (Full Load) / > 90 % (Half Load)
Lifetime up to 100,000 hours and more (Tc – 10 °C)
Suitable for luminaires of protection class I
Suitable for New OSRAM SELV and NON-SELV (SLIM)
Modules
Smooth Dimming behaviour
Effective Overtemperature Protection of the dimmable System
(Intelligent Thermomanagement of the Driver)
Very low Stand-By consumption < 0.3 W
Tc = +75 °C (max.)
Max. cable cross section for plug contact*:
“s”: 0.5...1.5 mm² / “f”: 0.75...1.5 mm²
* “s“ = “solid“ = Single-wire conductor, “f“ = Multi-wire conductor
SELV / NON-SELV System FIT
o Operation Area for SELV-/NON-SELV
Modules (Combination of Serial/Parallel
Module Connection)
Corridor Functionality on 3 Dimming Level Basis
o Triggered via Commodity Relay Presence-
Sensor or Push Button for 220-240V
o NO DALI Controls needed
TouchDIM RELEASE
o Auto Switch-Off @ sufficient Light
Levels
o Optimized Synchronity of DALI participants
in one control loop
o Suitable for Pulsating DC Input No
limitations in length of control loops
SMART Interface Driver/Module: Auto Current Set
Easy FIT for Emergency
o Automatic DC detection (0 Hz, Pulsating
DC (50/60 Hz), On/Off switchable)
o Configurable emergency power
characteristics (1…100 % Lum. Flux /
DEFAULT: 15% Arc. Power);
o Locking Functionality of DALI parameters
for Higher Safety (Read Only Mode)
o Re-Installation of AC Level/Conditions
before DC operation (Auto AC/DC)
Constant Lumen Output (CLO) / Flex. Current
Setting
o Compensation of Lm-Degeneration over
Module Lifetime
o Pre-Set CLO Functionalities
o Current Setting for highest Module-Variety
Power2Module Technology
o Power Boost Mode for Higher Lm-
Packages on demand / CLO via Flexible
Flag Setting
Smart Monitoring & Management
o Feedback of Power Consumption (High
Range/Resolution)
o Feedback of Detected Module & Module
Operation Counter (Resettable)
o Overvoltage Monitoring (Detection of up to
3 sep. OV events)
Switching b/w Linear/Logarithmic Dimming Curve
for Daylight Simulations / Special Effects
Memory Bank Usage: Public Information
Management w/ Internet XML description
GREY: Available > 2014
DALI product features
Compliance with the DALI standard to IEC 62386 latest
Edition 2012
DALI Control Input protected against overvoltage and polarity
reversal
Touch DIM® and Touch DIM® Sensor function: Manual
dimming (Touch DIM®) without any controller and with
standard switches, incl. memory function (double click) and
soft start (Last Switch-On Level)
Approbations (in July 2013)
Safety: to EN 61347-1, 61347-2-3, 61347-2-13, 62384
Lamp operation: to EN 60929
DALI standard: to IEC 62386 – 101, 102, 207
RFI requirements: to EN 55015: 2007+A1:2007 (300 MHz
compliance)/CDN
Line harmonics: to EN 61000-3-2
Immunity: to EN 61547
EL (Emergency Lighting): to IEC 61347-2-3 / App. J
Emergency Installation: to EN 60598-2-22
Suited for Central Battery Systems: to EN 50172
Approval marks in July 2013
STAND-BY
< 0.3W
EPBD
European
Building
Directive
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - LINEAR (non-isolated)

DALI (GII) Dimmable ECG for Current Sourced LED Modules Misprints and technical changes excepted Edition Oct

Page 2 - Edition June 2013

DALI (GII) Dimmable ECG for Current Sourced LED Modules Misprints and technical changes excepted 2Edition J

Page 3 - Iout [mA]

DALI (GII) Dimmable ECG for Current Sourced LED Modules Misprints and technical changes excepted 3Edition J

Page 4 - I III VIVII VI

DALI (GII) Dimmable ECG for Current Sourced LED Modules Misprints and technical changes excepted 4Edition J

Page 5 - I II III

DALI (GII) Dimmable ECG for Current Sourced LED Modules Misprints and technical changes excepted 5Edition J

Page 6

DALI (GII) Dimmable ECG for Current Sourced LED Modules Misprints and technical changes excepted 6Edition J

Page 7 - 3DIM ECG

DALI (GII) Dimmable ECG for Current Sourced LED Modules Misprints and technical changes excepted 7Edition J

Page 8

DALI (GII) Dimmable ECG for Current Sourced LED Modules Misprints and technical changes excepted 8Edition J

Comments to this Manuals

No comments